TEL: 020-87478566

GGJ reactive power compensation device

GGJ reactive power compensation device

Product Description:
GGJ reactive power compensation device is designed to improve power factor, reduce reactive power loss of power distribution system, and improve power quality. The product is advanced in design, reliable in technical performance, suitable for matching with different types of cabinets produced by different profiles, and easy to install and maintain. Use parallel capacitors to improve the power factor of asynchronous motors in continuous operation, inductive loads and power supply and distribution systems. This device can effectively save power, improve the load capacity of equipment, improve power quality, and control harmonic pollution. It is suitable for various power consumption At the same time, it is suitable for the product matching of different switchgear manufacturers, thus providing an effective guarantee for non-professional manufacturers to produce high-quality reactive power compensation devices.
This product is suitable for various low-voltage power distribution systems, low-voltage substations and various low-voltage power users.
This series of reactive power compensation devices complies with the standards of GB/T15576-2008 "Low Voltage Complete Reactive Power Compensation Devices".


产品详情

Features:
1. The controller setting is flexible, and single-phase compensation or three-phase compensation can be used according to the actual situation
2. The switching method is controlled by a microprocessor, and the capacitor is automatically switched according to the reactive power demand or power factor of the system.
3. Dynamic tracking and compensation of load reactive power, keeping the power factor above 0.95.
4. According to customer requirements, remote setting parameters, remote meter reading and three remote functions can be realized.

Working Environment:
1. The altitude does not exceed 2000M.
2. The short-term maximum temperature is 40°C, the 24-hour average maximum temperature is 35°C, and the minimum temperature is -5°C.
3. The annual average relative humidity of the air is not more than 90%.
4. Places without obvious severe vibration, impact and bumps.
5. There are no flammable and explosive materials, and there is no gas and conductor dust in the surrounding air that can corrode metals and damage insulation.


Technical Parameters:
A. Executive standard: GB/T15576-2008
B. Insulation voltage: ≤1000V
C. Working voltage: ≤450V
D. Working current: ≤800A
E. Protection level: ≤IP30

Dimensions:
Cabinet standard size H (mm) x W (mm) x D (mm)
Cabinet height (H): 2200
Cabinet width (W): 600, 800, 1000
Cabinet depth (D): 600, 800, 1000